Doverin Labs
Analytical testing for peptide products
| Client: | Reset Peptides |
|---|---|
| Accession #: | 26030026 |
| Search Code: | DVN26030026 |
| Received: | 03/21/2026 |
| Reported: | 03/23/2026 |
| Lot: | DOVN-2603-0026 |
Sample Summary
Product:BPC-157 + TB-500 - 10+10
Purity:99.41% / 99.33%
Identity:Confirmed against reference standard
Net Content:By component — see results
Molecular Formula:Not applicable (blend)
Molecular Weight:Not applicable (blend)
Appearance:White Lyophilized Powder
Chemical reference:BPC-157 PubChem / TB-500 supplied COA
Analytical Results
| Test | Result |
|---|---|
| Identity (LC-MS) | BPC-157, TB-500 |
| Purity (RP-HPLC-UV, area %) — BPC-157 | 99.41% |
| Purity (RP-HPLC-UV, area %) — TB-500 | 99.33% |
| Net Content — BPC-157 | 10.61 mg |
| Net Content — TB-500 | 10.89 mg |
Observations
- No molecular formula is assigned to this material. The reference source describes it as: Blend: C62H98N16O22 + C212H350N56O78S; 1419.5 + 4963.44 g/mol.
- Mass spectrum: no molecular weight is declared for this material, so the acquired m/z values are not assigned to charge states. The spectrum is published as acquired.
Method: purity by reversed-phase HPLC with UV detection, reported as peak area percent; identity by liquid chromatography–mass spectrometry (LC-MS) on the same sample. Full chromatographic conditions are held on file and issued on request against this search code.
Chromatogram
Mass Confirmation
Observed m/z: 355.882, 474.174, 710.757. No charge states are assigned — see observations above.

Frederick Johnson
Head of analytical chemistry
Scan to verify
doverinlabs.com/verify
DVN26030026